<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>48000</ErrorNumber>
<ErrorFamily>Media Handler</ErrorFamily>
<ErrorMessage>
MDH: Shuttle is unable to align media, ensure that there are &lt;Number of stacks&gt; stack(s) on the shuttle
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The shuttle was unable to align the media, which it does by moving the media to trigger
sensors on the side and then move a calibrated distance back.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><UnnumberedList>
<ListItem><Text>
Check to make sure the proper media is loaded on the shuttle, especially if using manual bypass
</Text></ListItem>
<ListItem><Text>
Check to make sure the media is loaded properly on the shuttle
</Text></ListItem>
</UnnumberedList></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
Wrongly specified media (loading panorama, but put two small stacks on instead)
</Cause>
<Cause>
Hardware interference
</Cause>
<Cause>
Faulty sensor.
</Cause>
<Parameter>
Number of stacks -
Number of media stacks expected on the shuttle
</Parameter>
<LastModified>
22-Nov-2007
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:53 2008 PST
</Updated>
<Links>
</Links>
</Error>